LigoWave APC

  • Updated

Initial Setup

Configure your PC with a static IP address on the 192.168.2.0 subnet (e.g., 192.168.2.10) with a subnet mask of 255.255.255.0.

Connect the APC Ethernet interface into the same physical network switch or port as your PC. Wait a few minutes for the AP to completely boot up.

Open a web browser and navigate to http://192.168.2.66 via the address bar.

The default username is admin and the default password is admin01 (unless these credentials have been modified previously).

Network & Wireless Configuration

Click on the Configuration tab on the top menu and then select Network from the sub-menu below it. On the Network Mode drop-down menu, select Router.

Still within the Configuration tab, select Wireless from the sub-menu and set the SSID field to the specific wireless network name you wish to broadcast.

Security & UAM Settings

In the Security section, click the Security drop-down menu and choose UAM. Configure the section with the following values:

Radius Server 1 *insert radius_server here*
Radius Server 2 *insert radius_server2 here*
Radius Secret *insert radius_secret here*
Radius Auth Port 1812
Radius Acct Port 1813
Radius Web Page Type External
UAM Login Page *insert access_url here*
UAM Secret *insert uam_secret here*

DHCP Server Settings

Interface IP Address 10.1.0.1
DHCP Server 10.1.0.1
Subnet Mask 255.255.255.0
DNS Server 1 10.1.0.1

In the White list section, add the required domains step-by-step by clicking the + icon to append entries. Please refer directly to this list for the exact values required.

Click on Apply & Save, then restart the hardware component to apply all configuration layers.

Configuration Complete

The configuration is now complete.